Factory price 200-240V Panic light ballast LED Emergency driver for triproof light down light ceiling light highbay light panel light wallpack emergency invert
1.self-detect
2.constant power emergency output
3.Suits for LED fitting with external LED driver
4.External battery,Li-ion/Li-FeP04/Ni-CD
5.With multi-protection function;
(1)battery overcharge protection;
(2)battery over-discharge protection;
(3)output overload protection;
(4)short-circuit protection.
5.Accessary test switch and LED indicator
6.In the state of the power off,to connect with the battery,static current at the battery terminal is 0uA
Item number |
MF-188B |
Input Voltage |
220~240VAC,50/60Hz |
Input Current |
100mA Max. |
Emergency Power |
3W/5W/8W/10W/12W |
Emergency Lasting Time |
90 Minutes,180 Minutes |
Output Voltage |
20-85VDC |
Battery Type |
Li-ion or Li-FeP04 |
Environment Temp. |
32~122F(0~50°C) |
Warranty |
3 Years |
Meas. |
L150*W38*H24mm |
Power factor |
≥0.5 @230 Vac |
IP Rating |
IP 20 |
Relevant standard |
IEC 61347-2-7/IEC 61347-1/EN55015 |


1.Have authorized CE,CB certificates
2.Constant current output
3.Apply to constant current led lighting products
4.Charging and dis-charging protection function
5.and over heat temp. protection
6.Mock-up electricity pause emergency testing function
7.Can be power off under emergency status
8.Indication light: city grid electricity, charging, fault
9.Seasonal self detect function
10Protection functions: over voltage, short circuit, over
load and open circuit
11.Metallic housing, comply EMC, FCC and C-tick ordinances
12.IP grade: IP20

1.Commercial Spaces (Malls/Office Buildings)
Used for emergency evacuation and decorative lighting, supports smart sensor integration, complies with EN 60598-2-22 standards, and maintains consistent color temperature during backup mode.
2.Industrial Explosion-Proof Environments (Oil/Chemical Plants)
Features intrinsically safe circuits and wide-temperature batteries, meeting IECEx/ATEX explosion-proof certifications for Zone 1/2 hazardous areas.
3.Residential/Public Facilities (Stairwells, Corridors)
Equipped with motion/audio sensors for automatic activation during power outages, providing 90+ minutes of backup lighting for safe evacuation.
4.Medical Facilities (Hospitals/Labs)
Ensures uninterrupted lighting in operating rooms and emergency zones with zero delay switching, meeting medical-grade EMC immunity requirements.
5.Outdoor/Tunnel Lighting
High ingress protection (IP66/IP67) with weather-resistant design, maintaining guidance lighting during emergencies.



LED and test button status:
LED INDICATOR
Green :In main power mode
Red:charging mode,when 95% charging red light off
Yellow:The battery is not connected, the battery is short-circuited, open-circuited
The emergency status indicators are all turned off
TEST BUTTON
1:0S<Key≤2S,Enter a simulated state of emergency,the green indicator blinks
once every second,keep emergency status for 3 seconds and back to normal status
2:3S<Key≤5S,The green indicator flashes twice in 1 second, enters the monthly self-test,
maintains the emergency state for 30 minutes and back to normal status
3:6S<Key,The green indicator flashes 5 times in 1 second, enters the annual self-test,
maintains the emergency state for 90 minutes and back to normal status
4:In the state of monthly inspection or annual inspection,
short press once to exit and return to the normal charging state
5:0S<Key≤1S,In the emergency state, the emergency state is turned off.
QUARTERLY SELF-TEST
when emergency driver is on power,every 90 days± 1 day
automatically enter the emergency state,emergency duration
until the battery is discharged,then return to power-on status.
LED indicator
Mounting hole 6.5mm dia
Test switch
Mounting hole 7mm dia
Installation Instructions
1:If it is used for the first time or it does not enter the normal working
state after being over-discharged, it is necessary to connect the main power
to activate the emergency power supply and charge it for 24 hours.
Please use the original emergency battery provided
2:When installing and using it, please keep it away from heat sources and only use
it within a certain working temperature range.
3:Should be stored in a cool, dry environment.
4:After prolonged storage, recharge at least once every 6 months as needed.
5:Emergency driver testing must be longer than 1min, don't press the testing button frequently.

Q1: Are you a factory or a trading company? Where is your company located?
A1: We are 100% a factory, not a trading company. Our company is located in Dongguan, between Shenzhen and Hongkong Guangzhou, China.
Q2. How about the lead time of LED Linear High Bay Light ?
A2: 3-7 days for sample order, 15-25 days for mass production order base on order quantities.
Q3. Can I have a sample order for LED Tri-proof Light ?
A3: Yes, sample order to test and check quality is welcomed. Mixed samples are acceptable.
Q4: How do you ship the finished production ?
A4:By SEA, AIR or Express(DHL,UPS,Fedex,TNT,etc) are optional.