Factory Price High-Intensity LED Type A Aviation Obstruction Light Durable & FAA-Compliant Maximum Visibility for High-Rise Building High Chimney
This LED Medium-intensity Type B L864 Aviation Obstruction Light flashing red color, designed for marking top of obstacle which height is more than 45meters.
Ultra high intensity CREE LED is used for the light source ensure the long life experience and good performance. Self-designed reflector is used to converge light, which could reach the standard light intensity with as less as the power consumption.
Products Parameters
SPECIFICATIONS |
MF-HI-A1 LED High-intensity Type A Aviation Obstruction Light |
Light Characteristics |
Light Source |
CREE high intensity LED |
Available Colors |
White |
Intensity(cd) |
≥200,000cd(Daytime)(ICAO Type A)
Optional:270,000cd±25%(Daytime)(FAAL-
≥20,000cd(Twilight)
≥2,000cd(Night) |
Horizontal Output(degrees) |
90 |
Vertical Divergence(degrees) |
3-7 |
Flash Characteristics |
40-60FPM(40fpm factory setting,others |
Operation Mode |
24hours operation,3 different modes |
LED Life Experience(hours) |
>100,000 |
Electrical Characteristics |
Operating Voltage |
DC(48VDC)or AC(110-240V)or others |
Average Power(W) |
<50W(40fpm) |
Circuit Protection |
Integrated |
Physical Characteristics |
Body Material |
Polycarbonate |
Base Material |
Powder coated die-casting aluminum |
Mounting |
140×54×012(mm) |
Dimension(mm) |
470×248×212 |
Weight(kg) |
10 |
Product Life Expectancy |
10 years Plus |
Environmental Factors |
Humidity |
0%-100% |
Temperature(ºC) |
-55ºC~70ºC |
Wind Speed |
80m/s |
Waterproof |
IP66 |
Compliance |
ICAO |
Annex 14 Volume 1,Aerodrome Design and
Operations'Eight edition 2018,table 6.3
High-intensity Type AWhite Obstacle Light |
FAA |
L-856,L-857 |
Options Available |
NVG(Night Vision Goggles)compatible LED
Dry Contact alarm(NO COM NC)
User adjustable flashing rate(40,50,60)
Solar power system |
MF-HI-A1 High-intensity light is used on the top of the High-rise Building, High Chimney, marking towers (Telecom, GSM, Microwave & TV), High Pole, Tower Crane, Wind Turbine, etc. when the obstacle height is more than 150meter, and most time work with low intensity lights & medium intensity light installed on the lower place.
1.Skyscrapers and Landmark Towers
Scenario Requirements:
Urban skyscrapers and TV towers (e.g., CN Tower, Oriental Pearl Tower) must comply with ICAO Annex 14 for daytime (white light) and nighttime (red light) warnings to prevent aircraft collisions.
Adaptability:
≥32,000cd White Light Intensity: Penetrates urban smog/light pollution for daytime visibility.
20-60 FPM Adjustable Flash Rate: Adapts to airspace control requirements (e.g., airport clearance zones).
200 km/h Wind Resistance: Withstands strong wind loads atop ultra-high-rise structures.
2. Energy Infrastructure
Scenario Requirements:
Offshore wind platforms, oil/gas drilling towers, and high-voltage transmission towers require long-term stability in harsh environments.
Adaptability:
IP66/IP67 Protection + Anti-Salt Spray Coating: Resists marine humidity and corrosion.
Wide Temperature Range (-50°C to +85°C): Suitable for Arctic wind farms or desert oil fields.
DC 12-48V Power Compatibility: Direct integration with wind/solar off-grid systems.
3. Communication and Broadcast Towers
Scenario Requirements:
5G communication towers and broadcast transmission towers (e.g., Lagos TV Tower in Nigeria) require minimal maintenance and lightning protection.
Adaptability:
IoT Remote Monitoring: Real-time alerts for LED failures or voltage anomalies, reducing maintenance risks.
10kV Integrated Lightning Protection Circuit: Safeguards sensitive communication equipment from surges.
50-300mm Diameter Mounting Kits: Rapid installation on conical/cylindrical towers.
4. Airport Clearance Zones and Flight Path Obstacles
Scenario Requirements:
Temporary obstacles like construction cranes near airports must comply with FAA L-864 standards for quick deployment.
Adaptability:
Modular Design: Assembly completed in 15 minutes for temporary warnings.
620-640nm Red Light Wavelength:
Avoids spectral interference with airport runway lights.
Optional GPS Anti-Theft:
Monitors unauthorized movement (e.g., theft at construction sites).
5. Special Industrial Facilities
Scenario Requirements:
Chemical plant chimneys and LNG storage areas require explosion-proof design and aviation hazard prevention.
Adaptability:
ATEX-Certified Base: Complies with Zone 2 flammable gas environments.
Vibration-Resistant Structure: Prevents component loosening from industrial vibrations.
UV-Free Design: Avoids material degradation in high-temperature storage areas.
Remark: The first line is the factory setting if no special request.
Installation and Operation
1.Please install the lamp horizontally, and the installation place is strong enough for holding the light; the installation bracket is customized according to the mounting place.
2.When installing, please DO NOT face the photocell to the light source nearby, and the photocell won't be affected by nearby objects.
3.Before wiring, please confirm that the power supply voltage is the same as the lamp power input voltage.
4.Correctly connect the power cable according to the corresponding label on the cable.
5.After connecting the wires, check that the wiring is correct before turning on the power. After turning on the power, the light starts to work normally.
6.Please test the GPS synchronization function at open area outdoor. The synchronization takes about 1-10
minutes. (Only suitable for the type with GPS synchronization).
Cautions
1High-power lamps, with high temperature at surface, cannot be covered, and the shortest distance between the
surface of the illuminated object and the lamp is not less than 3 meters to avoid burns or fire.
2.Please ensure that the power supply voltage is the same as the label before use.
3.This product will have a temperature rise when working which is normal.
4.When the product is working, do not open any part of the lamp body to avoid danger.
5.This product is a sealed structure. Non-professional maintenance personnel should not disassemble it. Once
found, our company will not guarantee it.
6.When the product is working, do not look directly at the lamp in a horizontal direction to avoid eye injury
Installation Wiring diagram
(Mounting bracket is charged separately, and size is customized)
Production Test

FAQ
Q1: What do you sell?
A1: We provide good quality of floodlight, high bay light, explosion proof light, tri-proof light, downlight, and other lighting products, as well as responsible services and reliable after-sales warranty.
Q2: Is it OK to print my logo on led light product?
A2: Yes. We provide ODM and OEM services. Please inform us formally before our production and confirm the design firstly based on our sample.
Q3: How to deal with the faulty?
A3: During the guarantee period, we will send new lights with new order for small quantity. For defective batch products, we will repair them and resend them to you or we can discuss the solution including re-call according to real situation.
Q4: Can I have a sample order for led light?
A4: Yes, we welcome sample order to test and check quality. One sample or mixed samples are acceptable.
Q5: How long time to ship the goods if place an order?
A5: Usually 7 days for sample or small order,15 working days for bulk order, but sometimes depend on the order quantity.